TAP

Rimmed Hammerset Anchor

Hammerset anchor with metric internal thread M6 - M16 for medium load range for anchoring in non-cracked concrete C20/25 - C50/60 and for multiple fixings of non-load bearing systems in concrete.  

Označení CE
ETA
Servisní třída 2
Elektroizolační ocel
Feu R 120
Fix Calc

Podrobnosti produktu

Obrázky

Vlastnosti

Material

  • Steel
  • White zinc plated

Benefits

  • Safe and controlled expansion
  • Fast application
  • Shallow embedment depth
  • Rimmed plug version for easy installation flush with base material
  • High strength in relation to embedment depths
  • Fire resistance R120

Aplikace

Applications

  • Suspended ceiling applications
  • Pipework
  • Sprinkler systems

Suitable for

  • Multiple use for non-structural
  • applications on cracked
  • and non-cracked concrete
  • Solid stone

Technické údaje

Rozměry

Product Dimensions

Art. nr. Product Reference Dimensions [dxL] [mm] Hole diameter [do] [mm] Cylindrical hole depth [h0] [mm] Nominal embedment depth [hnom] [mm] Threaded length [Lth] [mm] Max. thread engagement [Ls,min] [mm] Torque [Tinst] [Nm] Qty per box Qty per outer box
75205B0600000TAPM6x25*8252511641002000
75205B0800000M8x3010303013881001000
75205B1000000M10x40124040171015100600
75205B1200000M12x5015505021123550300
75205B1600000M16x65**20656530166025150

*  Only ETA 18/0433 ETAG 001 p.6 Multiple use
** Only ETA 18/0432 EAD-330232-00-0601 opt.7

Screw Length: Minimum: Ls,min + tfix  -  Maximum: Lth + tfix

tool

Art. nr. Product Reference Ds [mm] Hs [mm] Qty per box
75205B0600000TAP--100
75205B0800000TAP--100
75205B1000000TAP--100
75205B1200000TAP--50
75205B1600000TAP--25
49002B060000CTAP SWZ-M64.8151
49002B080000CTAP SWZ-M86.6181
49002B100000CTAP SWZ-M107.8251
49002B120000CTAP SWZ-M129.6301
49002B160000CTAP SWZ-M1613.5381

Design capacities - single anchor - no edge distances - ETA-18/0432

Art. nr. Recommented loads - Non-cracked concrete (3)
Dimensions [dxL] [mm] Tension - Nrec(1) Shear - Vrec (1-2)
C20/25 [kN] C30/37 [kN] C40/50 [kN] C50/60 [kN] C20/25 [kN] C30/37 [kN] C40/50 [kN] C50/60 [kN]
75205B0600000M6x25*--------
75205B0800000M8x303.344.75.144.95.66.2
75205B1000000M10x405.16.27.27.96.17.48.69.5
75205B1200000M12x506.17.48.69.58.510.41213.2
75205B1600000M16x65**9.912.11415.325.230.735.635.9
49002B060000CM6--------
49002B080000CM8--------
49002B100000CM10--------
49002B120000CM12--------
49002B160000CM16--------

1. The design loads loads have been calculated using the partial safety factors for resistances stated in ETA-approval(s). The loading figures are valid for unreinforced concrete and reinforced concrete with a rebar spacing s ≥ 15 cm (any diameter) or with a rebar spacing s ≥ 10 cm, if the rebar diameter is 10mm or smaller.
2. The figures for shear are based on a single anchor without influence of concrete edges. For anchorages close to edges (c ≤ max [10 hef; 60d]) the concrete edge failure shall be checked per ETAG 001, Annex C, design method A.
3. Concrete is considered non-cracked when the tensile stress within the concrete is\sigmaL +\sigmaR ≤ 0. In the absence of detailed verification\sigmaR = 3 N/mm² can be assumed (\sigmaL equals the tensile stress within the concrete induced by external loads, anchors loads included).

*Not covered by ETA-18/0432

Recommended capacities - multiple use cracked and un-cracked concrete ETA-18/0433

Art. nr. Product Reference Dimensions [dxL] [mm] cracked and uncracked concrete
tension / shear load Rrec [kN]
75205B0600000TAPM6x25*0.5
75205B0800000TAPM8x300.7
75205B1000000TAPM10x401
75205B1200000TAPM12x501.4
75205B1600000TAPM16x65**-
49002B060000CTAP SWZ-M6M6-
49002B080000CTAP SWZ-M8M8-
49002B100000CTAP SWZ-M10M10-
49002B120000CTAP SWZ-M12M12-
49002B160000CTAP SWZ-M16M16-

The design loads FRD derive from the characteristic loads on the ETA certification and are inclusive of the partial safety factors γM

The recommended loads F derive from the characteristic loads on the ETA certification and are inclusive of the partial safety factors γF=1.4 and γM

Instalace

Instalace

Installation data

Art. nr. Product Reference Dimensions [dxL] [mm] Ø drilling hole [d0] [mm] Min. drill depth [h1] [mm] Ø drilling fixture [df] [mm] Installation torque [Tinst] [Nm] Embedment depth [hef] [mm] Min. support thickness [hmin] [mm]
75205B0600000TAPM6x25*8257425-
75205B0800000TAPM8x3010309830100
75205B1000000TAPM10x401240121540100
75205B1200000TAPM12x501550143550100
75205B1600000TAPM16x65**2065186065130
49002B060000CTAP SWZ-M6M6------
49002B080000CTAP SWZ-M8M8------
49002B100000CTAP SWZ-M10M10------
49002B120000CTAP SWZ-M12M12------
49002B160000CTAP SWZ-M16M16------

Spacing and edge distances - ETA-18/0432

Art. nr. Product Reference Dimensions [dxL] [mm] Min. edge distance [cmin] [mm] Min. spacing [smin] [mm] Characteristic edge distance [ccr,N] [mm] Characteristic spacing(5) - Scr,N [scr,N] [mm]
75205B0600000TAPM6x25*----
75205B0800000TAPM8x3041414590
75205B1000000TAPM10x40545460120
75205B1200000TAPM12x50686875150
75205B1600000TAPM16x65**888897195
49002B060000CTAP SWZ-M6M6----
49002B080000CTAP SWZ-M8M8----
49002B100000CTAP SWZ-M10M10----
49002B120000CTAP SWZ-M12M12----
49002B160000CTAP SWZ-M16M16----

* Not included in the approval

Spacing and edge distance ETA-18-0433

Art. nr. Product Reference Dimensions [dxL] [mm] Embedment depth hef [mm] Min. support thickness hmin [mm] Min. edge distance [cmin] [mm] Min. spacing [smin] [mm]
75205B0600000TAPM6x25*2580200150
75205B0800000TAPM8x303080200150
75205B1000000TAPM10x404080200150
75205B1200000TAPM12x5050100200150
75205B1600000TAPM16x65**----
49002B060000CTAP SWZ-M6M6----
49002B080000CTAP SWZ-M8M8----
49002B100000CTAP SWZ-M10M10----
49002B120000CTAP SWZ-M12M12----
49002B160000CTAP SWZ-M16M16----

Certifikace

Prohlášení o funkčnosti (DoP)

cz-tap-02-f.pdf (227.42 KB)

Evropské technické posouzení (ETA)

Buy from Distributor

No items available.

Contact

Simpson Strong-Tie Německo

Simpson Strong-Tie GmbH

Hubert-Vergölst-Straße 6-14
61231 Bad Nauheim
Německo