Heavy Duty Three Segments Through Anchor
The FM-MP3 evo is an anchor made of galvanised steel, which is placed into a drilled hole and anchored by torque-controlled expansion.
Podrobnosti produktu
Vlastnosti
Material
- Steel
- White zinc plated
Benefits
- Universal metallic anchor even for hollow base materials
- Single shell body with exclusive cone containing system
- Accessories for all types of fixing requirements
- Fire resistance R120
Aplikace
Applications
- Safety barriers
- Fencing
- Railings
Suitable for
- Multiple use for non-structural applications on cracked and non-cracked concrete
Technické údaje
Product Dimensions Anchor Only
Art. nr. | Product Reference | Dimensions [ØxL] [mm] | Max. fixture thickness [tfix] [mm] | Hole diameter [do] [mm] | Min. hole depth [h1] [mm] | Nominal embedment depth [hnom] [mm] | Min. setting depth [hef] [mm] | Hole diameter in fixing element [df] [mm] | Min. fixture thickness [hmin] [mm] | Torque [Tinst] [Nm] | Qty per box | Qty per outer box |
---|---|---|---|---|---|---|---|---|---|---|---|---|
73300B1004500 | FM-MP3 evo | M6x45* | - | 10 | 60 | 45 | 36 | 8 | 100 | 8 | 50 | 500 |
73300B1205000 | M8x50* | - | 12 | 70 | 50 | 43 | 10 | 100 | 15 | 50 | 500 | |
73300B1506000 | M10x60* | - | 15 | 80 | 60 | 50 | 12 | 100 | 30 | 25 | 250 | |
73300B1808000 | M12x80* | - | 18 | 100 | 80 | 69 | 14 | 140 | 50 | 20 | 200 |
*Certified product when coupled with hex head screw DIN933 grade 8.8 and washer DIN125-1 (tfix = Lv – hnom)
Product Dimensions Hex Head Screw
Art. nr. | Product Reference | Dimensions [ØxL] [mm] | Max. fixture thickness [tfix] [mm] | Hole diameter [do] [mm] | Min. hole depth [h1] [mm] | Nominal embedment depth [hnom] [mm] | Min. setting depth [hef] [mm] | Hole diameter in fixing element [df] [mm] | Min. fixture thickness [hmin] [mm] | Thread length [Lv] [mm] | Torque [Tinst] [Nm] | Qty per box | Qty per outer box |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
73301B1004500 | FM-MP3 evo | M6x45 | 5 | 10 | 60 | 45 | 36 | 8 | 100 | 50 | 8 | 50 | 500 |
73301B1205000 | M8x50 | 10 | 12 | 70 | 50 | 43 | 10 | 100 | 60 | 15 | 50 | 250 | |
73301B1506000 | M10x60 | 20 | 15 | 80 | 60 | 50 | 12 | 100 | 80 | 30 | 25 | 125 | |
73301B1808000 | M12x80 | 20 | 18 | 100 | 80 | 69 | 14 | 140 | 100 | 50 | 20 | 100 |
** Not covered by CE certification
Product Dimensions Forged Cup Hook
Art. nr. | Product Reference | Dimensions [ØxL] [mm] | Hole diameter [do] [mm] | Min. hole depth [h1] [mm] | Nominal embedment depth [hnom] [mm] | Min. setting depth [hef] [mm] | Min. fixture thickness [hmin] [mm] | Thread length [Lv] [mm] | Internal Ø hook or eye [O] [mm] | Torque [Tinst] [Nm] | Qty per box | Qty per outer box |
---|---|---|---|---|---|---|---|---|---|---|---|---|
73303B1004500 | FM-MP3 evo | M6x45** | 10 | 60 | 45 | 36 | 100 | 50 | 9.5 | 5 | 50 | 500 |
73303B1205000 | M8x50** | 12 | 70 | 50 | 43 | 100 | 60 | 11 | 10 | 50 | 250 | |
73303B1506000 | M10x60** | 15 | 80 | 60 | 50 | 100 | 73 | 14 | 20 | 25 | 125 | |
73303B1808000 | M12x80** | 18 | 100 | 80 | 69 | 140 | 90 | 16 | 30 | 20 | 80 |
**Not covered by CE certification
Product Dimensions Forged Eye
Art. nr. | Product Reference | Dimensions [ØxL] [mm] | Hole diameter [do] [mm] | Min. hole depth [h1] [mm] | Nominal embedment depth [hnom] [mm] | Min. setting depth [hef] [mm] | Min. fixture thickness [hmin] [mm] | Thread length [Lv] [mm] | Internal Ø hook or eye [O] [mm] | Torque [Tinst] [Nm] | Qty per box | Qty per outer box |
---|---|---|---|---|---|---|---|---|---|---|---|---|
73304B1004500 | FM-MP3 evo | M6x45** | 10 | 60 | 45 | 36 | 100 | 50 | 10 | 5 | 50 | 500 |
73304B1205000 | M8x50** | 12 | 70 | 50 | 43 | 100 | 60 | 11.5 | 10 | 50 | 250 | |
73304B1506000 | M10x60** | 15 | 80 | 60 | 50 | 100 | 73 | 14.5 | 20 | 25 | 125 | |
73304B1808000 | M12x80** | 18 | 100 | 80 | 69 | 140 | 90 | 17 | 30 | 20 | 80 |
**Not covered by CE certification
Recommended loads / for single anchors / with no edge distances or spacings - ETA-09/0067
Art. nr. | Product Reference | Dimensions [ØxL] [mm] | Design capacity - Non-cracked concrete (3) | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Tension - Nrec1) | Shear - Vrec (1-2) | Bending moment MRd [Nm] | |||||||||
C20/25 [kN] | C30/37 [kN] | C40/50 [kN] | C50/60 [kN] | C20/25 [kN] | C30/37 [kN] | C40/50 [kN] | C50/60 [kN] | ||||
73300B1004500 | FM-MP3 evo | M6x45* | 3.6 | 4.4 | 5.1 | 5.6 | 3.7 | 3.7 | 3.7 | 3.7 | 7 |
73300B1205000 | FM-MP3 evo | M8x50* | 5.7 | 7 | 8 | 8.8 | 6.8 | 8.2 | 8.2 | 8.2 | 17 |
73300B1506000 | FM-MP3 evo | M10x60* | 8.3 | 10.4 | 12 | 13.2 | 8.5 | 10.3 | 12 | 13.2 | 34 |
73300B1808000 | FM-MP3 evo | M12x80* | 11.9 | 14.5 | 16.8 | 18.4 | 19.3 | 19.3 | 19.3 | 19.3 | 60 |
1. The recommended loads have been calculated using the partial safety factors for resistances stated in ETA-approval(s) and with a partial safety factor for actions of γF=1.4. The loading figures
are valid for unreinforced concrete and reinforced concrete with a rebar spacing s ≥ 15 cm (any diameter) or with a rebar spacing s ≥ 10 cm, if the rebar diameter is 10 mm or smaller.
2. The figures for shear are based on a single anchor without influence of concrete edges. For anchorages close to edges (c ≤ max [10 hef; 60d]) the concrete edge failure shall be checked per
ETAG 001, Annex C, design method A.
3. Concrete is considered non-cracked when the tensile stress within the concrete is\sigmaL +\sigmaR ≤ 0. In the absence of detailed verification\sigmaR = 3 N/mm² can be assumed (\sigmaL equals the tensile
stress within the concrete induced by external loads, anchors loads included).
* The above load values also apply to: evo S
Recommended loads / for single anchors / with no edge distances or spacings - ETA-10/0074
Art. nr. | Product Reference | Dimensions [ØxL] [mm] | Design capacity - cracked and Non-cracked concrete |
---|---|---|---|
Tension and Shear - Frec [kN] - C20/25-C50/60 | |||
73300B1004500 | FM-MP3 evo | M6x45* | 2.9 |
73300B1205000 | FM-MP3 evo | M8x50* | 5.7 |
73300B1506000 | FM-MP3 evo | M10x60* | 7.6 |
73300B1808000 | FM-MP3 evo | M12x80* | 9.5 |
1. The recommended loads have been calculated using the partial safety factors for resistances stated in ETA-approval(s) and with a partial safety factor for actions of γF=1.4. The loading figures
are valid for unreinforced concrete and reinforced concrete with a rebar spacing s ≥ 15 cm (any diameter) or with a rebar spacing s ≥ 10 cm, if the rebar diameter is 10 mm or smaller.
2. The figures for shear are based on a single anchor without influence of concrete edges. For anchorages close to edges (c ≤ max [10 hef; 60d]) the concrete edge failure shall be checked per
ETAG 001, Annex C, design method A.
3. Concrete is considered non-cracked when the tensile stress within the concrete is\sigmaL +\sigmaR ≤ 0. In the absence of detailed verification\sigmaR = 3 N/mm² can be assumed (\sigmaL equals the tensile stress within the concrete induced by external loads, anchors loads included).
* The above load values also apply to: evo S
Instalace
Instalace
Spacings and edge distances - ETA-09/0067
Art. nr. | Product Reference | Dimensions [ØxL] [mm] | Min. edge distance [cmin] [mm] | Min. spacing [smin] [mm] | Characteristic edge distance [ccr,N] [mm] | Characteristic spacing(5) - Scr,N [scr,N] [mm] |
---|---|---|---|---|---|---|
73300B1004500 | FM-MP3 evo | M6x45* | 35 | 35 | 54 | 108 |
73300B1205000 | FM-MP3 evo | M8x50* | 45 | 45 | 65 | 130 |
73300B1506000 | FM-MP3 evo | M10x60* | 50 | 50 | 75 | 150 |
73300B1808000 | FM-MP3 evo | M12x80* | 75 | 75 | 104 | 208 |
* The above table values also apply to: evo S
Spacings and edge distances - ETA-10/0074
Art. nr. | Product Reference | Dimensions [ØxL] [mm] | Characteristic spacing(5) - Scr,N [scr,N] [mm] | Characteristic edge distance [ccr,N] [mm] | Min. edge distance [cmin] [mm] | Min. spacing [smin] [mm] |
---|---|---|---|---|---|---|
73300B1004500 | FM-MP3 evo | M6x45* | 35 | 35 | 200 | 100 |
73300B1205000 | FM-MP3 evo | M8x50* | 45 | 45 | 200 | 130 |
73300B1506000 | FM-MP3 evo | M10x60* | 50 | 50 | 200 | 150 |
73300B1808000 | FM-MP3 evo | M12x80* | 75 | 75 | 200 | 210 |
* The above table values also apply to: evo S